Yumizen G Series Reagents (Yumizen G Range Reagents)
- In stock
- text_sku
HORIBA Medical's Yumizen G DDi reagent kit is available for the extensive Yumizen G hemostasis product line, covering the needs of any laboratory. The dedicated portfolio of coagulation instruments includes the fully automatic Yumizen G800, Yumizen G1500 and Yumizen G1550, as well as the semi-automatic Yumizen G200 and Yumizen G400 analyzers.
Horiba Medical's hemostasis reagent kits include a wide range of tests for both standard screening parameters and specialized tests to assess the potential risk of bleeding or thrombotic events.
The Prothrombin Time (PT) test using thromboplastin is available in lyophilized or liquid form and is intended for general evaluation of the extrinsic coagulation pathway or for monitoring oral anticoagulant therapy with vitamin K antagonists such as warfarin. Activated partial thromboplastin time (APTT) is used as a test for the diagnosis of hemophilia (A, B, and C) and is also used to monitor unfractionated heparin (UFH) therapy. In addition, Horiba Medical offers solutions for determining functional fibrinogen and thrombin time. The coagulation parameter D-dimer is used to exclude thrombosis of any etiology, monitor thrombolytic therapy, and the Antithrombin III test is used as a standard diagnostic parameter for thrombophilia.
Screening tests allow the detection of coagulation abnormalities
Hemostatic screening tests, Prothrombin Time (PT) and Activated Partial Thromboplastin Time (APTT), are frequently used to assess the bleeding risk, for example before an operation or an invasive procedure. These tests can detect coagulation abnormalities (with the exception of factor XIII deficiency) but are not suitable for primary hemostasis disorders.
HORIBA Medical offers a new range of liquid, ready-to-use reagents for more accurate global screening tests:
- Yumizen G PT Liq
- Yumizen G APTT Liq 4
The Thrombin Time is a screening test to assess abnormalities of fibrinogen and to detect inhibitors against thrombin or fibrin.
- Yumizen G TT, a human thrombin for perfect assessment of fibrin formation.
Fibrin formation and degradation
D-dimers is degradation products of fibrin, biomarker for activation of plasma coagulation and/or fibrinolysis.
Yumizen G DDi 2, the universal reagent, liquid & ready to use for semi-auto and full-auto systems.
Onboard stability of two weeks.
Venous Thromboembolism
An age-adjusted D-dimer cutoff combined with probability assessment ruled out the diagnosis of Pulmonary Embolism (PE) in emergency department patients with suspected PE. The D-dimer result should be interpreted according to the age-adjusted cutoff
- In patients younger than 50 years, PE is excluded if D-dimer value < 500 micrograms/L.
- In patients 50 years or older, PE is excluded if D-dimer value < age multiplied by 10.
Disseminated Intravascular Coagulation (DIC)
Elevated DDi implies the involvement of fibrinolysis secondary to coagulation activation, which is very interesting in the diagnosis of DIC. A normal level of D-dimer has excellent negative predictive value. Measurements of D-dimer levels is useful to monitor to capture the course of the disease.
COVID patients
D-dimer is correlate with disease severity and a reliable prognostic biomarker for in-hospital mortality in patients admitted for COVID-19.
Thrombophilia
Thrombophilia is a disorder of haemostasis in which there is a tendency for the occurrence of thrombosis. This tendency can be inherited or acquired. HORIBA Medical offer a comprehensive range of screening assays for thrombophilia.
- Protein S
- Protein C
- Antithrombin
- Lupus anticoagulants: DRVVT and APTT pathways
Diagnosis of Antiphospholipid Syndrome
Antiphospholipid syndrome is defined by the presence of persistent antiphospholipid antibodies in patients with vascular thrombosis or pregnancy morbidity. HORIBA Medical offers the full range of reagents for the diagnosis of lupus anticoagulants by both the DRVVT and APTT pathways according to the international guidelines:
- DVVtest® 10/ DVV Confirm® 5
- Yumizen G APTT Liq 4 / Yumizen G APTT
Anticoagulant monitoring
VKA therapy inhibits factors II, VII, IX, and X and causes a prolonged PT.
Monitoring of vitamin K anticoagulants (VKAs)
VKAs can prevent stroke or systemic embolization among patients with atrial fibrillation and can treat and prevent venous thromboembolism. The impact of VKAs on clotting is assessed via the International Normalized Ratio: INR = (PT patient/MNPT)ISI
HORIBA Medical offers a comprehensive range for monitoring of VKA therapy:
- Yumizen G PT Liq 4: the universal reagent, liquid & ready to use for semi-auto and full-auto systems.
- INR Kit: the unit test adapted to the needs of clinics and satellite laboratories working with whole blood and plasma.
Monitoring of heparins
Heparin is a commonly used medication in the treatment and prophylaxis of thromboembolic disorders effective for prevention and treatment of venous thrombosis and pulmonary embolism, for prevention of mural thrombosis after myocardial infarction and for treatment of patients with unstable angina.
- ACTICHROME Heparin Anti-Xa* is a specific, easy to use and fully automated test. Dedicated calibration curves for greater accuracy of your unfractionated heparin and low molecular weight heparin measurement. It is the solution of choice for UFH, LMWH testing.
*available soon
|
Reference |
Product Name |
Formulation |
Packaging |
Systems |
|
Screening Reagents |
||||
|
1300036338 |
Yumizen G PT 5 |
Lyophilized |
5 x 5ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036373 |
Yumizen G PT liq 4 |
Liquid |
12 x 4ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036376 |
Yumizen G PT Reco 10 |
Lyophilized |
10 x 10ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036377 |
Yumizen G APTT 4 |
Lyophilized |
6 x 4ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036379 |
Yumizen G APTT liq 2 |
Liquid |
6 x 2ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036381 |
Yumizen G APTT liq 4 |
Liquid |
12 x 4ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036383 |
Yumizen G FIB 2 |
Lyophilized |
12 x 2ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036384 |
Yumizen G FIB 5 |
Lyophilized |
12 x 5ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036382 |
Yumizen G TT |
Lyophilized |
12 x 3ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036417 |
Yumizen G INR kit |
Lyophilized |
25 tests |
Yumizen G100 |
|
Thrombophilia |
||||
|
1300081526 |
ACTICLOT Protein S * |
Lyophilized |
4 x (1 mL + 1 mL) |
Yumizen G1500-1550/G800 |
|
1300081527 |
ACTICLOT C * |
Lyophilized |
3 x (1.5 mL + 1.5 mL) |
Yumizen G1500-1550/G800 |
|
1300036390 |
Yumizen G AT * |
Lyophilized |
4 x 3 mL |
Yumizen G1500-1550/G800/G400/G200 |
|
1300081528 |
ACTICHROME ATIII * |
Lyophilized |
6 x (2 + 2 + 5 mL) |
Yumizen G1500-1550/G800 |
|
1300079431 |
DVVtest10 ** |
Lyophilized |
10 x 2 mL |
Yumizen G1500-1550/G800 |
|
1300079433 |
DVVconfirm 5 ** |
Lyophilized |
10 x 1 mL |
Yumizen G1500-1550/G800 |
|
Fibrin Formation & Degradation |
||||
|
1300036391 |
Yumizen G DDi 2 |
Liquid |
3 x 6.5ml |
Yumizen G1500-1550/G800/G400/G200 |
|
Anticoagulant Therapy |
||||
|
300081662 |
ACTICHROME Heparin (Anti-FXa) |
Lyophilized |
4 x (5 + 5 + 5 mL) |
Yumizen G1500-1550/G800 |
|
Auxiliary Reagents |
||||
|
1300036386 |
Yumizen G CaCl2 4 |
Liquid |
12 x 4ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036385 |
Yumizen G IMIDAZOL |
Liquid |
12 x 15ml |
Yumizen G1500-1550/G800/G400/G200 |
|
1300036418 |
Yumizen G SORB |
Liquid |
12 x 15ml |
Yumizen G1500-1550/G800 |
|
1300036420 |
Yumizen G CLEANER |
Liquid |
4.5 L |
Yumizen G1500-1550/G800 |
|
1300036421 |
Yumizen G Clean SYS |
Liquid |
0.1 L |
Yumizen G1500-1550/G800 |
|
Controls & Calibrators |
||||
|
1300036412 |
Yumizen G CTRL l & ll |
Lyophilized |
5 x 1ml (2x) |
Yumizen G1550/G800/G400/G200 |
|
1300036416 |
Yumizen G CAL |
Lyophilized |
12 x 1ml |
Yumizen G1550/G800/G400/G200 |
|
1300036414 |
Yumizen G CTRL DDi I & II |
Lyophilized |
5 x 1 mL (x2) |
Yumizen G1550/G800/G400/G200 |
|
1300079434 |
LAtrol Abnormal Control Plasma ** |
Lyophilized |
10 x 0.5 mL |
Yumizen G1550/G800 |
|
1300079435 |
LAtrol Normal Control Plasma ** |
Lyophilized |
10 x 1 mL |
Yumizen G1550/G800 |
|
1300081529 |
Special Coagulation Control Normal * |
Lyophilized |
10 x 1 mL |
Yumizen G1550/G800 |
|
1300081560 |
Special Coagulation Control Abnormal * |
Lyophilized |
10 x 1 mL |
Yumizen G1550/G800 |
|
1300081561 |
Special Coagulation Calibrator PC/PS/AT * |
Lyophilized |
6 vials |
Yumizen G1550/G800 |
|
1300081563 |
ACTICHROME Heparin UFH Control Set * |
Lyophilized |
5 x (1 mL + 1 mL) |
Yumizen G1550/G800 |
|
1300081564 |
ACTICHROME Heparin LMWH Control Set * |
Lyophilized |
5 x (1 mL + 1 mL) |
Yumizen G1550/G800 |
|
1300081565 |
ACTICHROME Heparin UFH Calibrator Set * |
Lyophilized |
2 x (5 vials 1 mL) |
Yumizen G1550/G800 |
|
1300081566 |
ACTICHROME Heparin LMWH Calibrator Set * |
Lyophilized |
2 x (5 vials 1 mL) |
Yumizen G1550/G800 |
|
Consumables |
||||
|
1300036425 |
Yumizen G Cuvettes |
|
2 x 500 cuvettes |
Yumizen G1550/G800/G400/G200 |
|
1300039490 |
Magnetic stirrers |
|
10 |
Yumizen G1550/G800/G400/G200 |
|
1300039292 |
Yumizen G100 plunger pipette 20 μl |
|
1 |
Yumizen G100 |
|
1300039293 |
Yumizen G100 plugged pipette 20 μl |
|
1 |
Yumizen G100 |
|
1300039294 |
Yumizen G400 printer paper (1 roll) |
|
1 |
Yumizen G100 |
|
Accessories |
||||
|
1300047687 |
External Barcode Reader |
|
1 |
Yumizen G1550/G800/G400/G200 |
|
1300046575 |
UPS |
|
1 |
Yumizen G1550/G800 |
|
1300046576 |
Screen Arm Support |
|
1 |
Yumizen G1550/G800 |
|
1300083167 |
Adaptor 18/24 |
|
1 |
Yumizen G1550/G800 |
|
1300083168 |
Adaptor 18/32 |
|
1 |
Yumizen G1550/G800 |
|
1300071527 |
Insert for sample rack |
|
10 |
Yumizen G1550/G800 |
|
1300062211 |
Printer for Yumizen G200 |
|
1 |
Yumizen G200 |